FLOATING LEVEL SWITCH Performance Range The SK-12A float level switch is a ball-type mechanical switch, encased in a PVC housing that seals the switch mechanism in an air filled watertight chamber. Due to the enclosed air section, the SK-12A will attempt to float in liquid with an SG ≥ 1. The float level is used for level detection and dry run protection in bulk water reservoirs. Oprating Limits Liquid Temperature 0 - 55°C (but not frozen) Ambient Temperature 0 - 45°C
Technical Features Rated Voltage: 220VAC, 50Hz Maximum current: 16 Amp Protection grade: IP68 Cable length: 5m
PRESSURE BOOSTER SYSTEM COMPONENTS This pressure boost system comprises of: - 5-way connector (brass) - Pressure gauge - Pressure switch (see next page) - Non-return valve (1” brass) - Flexible hose (1”x1”x0.8m) - Flexible hose (1”x1”x0.4m) - Suction Hose Kit 25mm
PRESSURE SWITCH: SK-2 Performance Range The SK-2 is a mechanical type of pressure switch used to control electric driven domestic type pumps. When the internal pressure of the pipe is more than the setting pressure, the pressure control will disconnect the load power supply to the pump and connect the power again when pressure drops below the set pressure. The SK-2 has two operating points; one on the rising pressure trip point and the other on the falling pressure (reset point). The differential is the difference in pressure between the trip point (cut-out) and the reset point (cut-in).
Operating Limits Ambient Temperature: 0 - 55°C (but not frozen)
Technical Features Rated Voltage: 220VAC, 50Hz Maximum current: 12 Amp Protection grade: IP20 Pre-set on-off pressure: 1.4 - 2.8bar Maximum pressure: 6bar Joint screw: G1/4”
PRESSURE TANKS: BLADDER TYPE Performance Range The bladder type series of pressure tanks is designed to provide reliable storage for pressurized water in a booster pump system. The pressure tank effectively releases its stored volume of pressurised water on demand and prevents pump start-ups for demands lower than its storage capacity. The internal bladder ensures that there is no contact between the water and the air.
Operating Limits Liquid Temperature EPDM 0°C to 99°C Ambient Temperature up to 45°C Max. Working Pressure 10 bar
Technical Features Material Carbon Steel Bladder EPDM Orientation Vertical or horizontal Connections 1” - 11/4” BSP Capacity 24l, 60l, 100l, 300l
FLOW CONTROL SWITCH: SKD-2 Performance Range Flow from 0 to 6m3/h. The SKD-2 flow control starts the pump automatically when pressure decreases (for example taps are opened) and stops it when there is no flow/water shortage (for example taps are closed). It can be used for drinking water or non-portable water piping systems.
Operating limits Pipe Water Temperature 0 - 60°C (but not frozen) Ambient Temperature 0 - 45°C
Technical Features Rated Voltage: 220VAC, 50Hz Maximum current: 10 Amp Protection grade: IP65 Starting pressure: 1.5bar Maximum pressure: 10bar Inlet/outlet size: (1" x 1") BSP
REPLACEABLE PC BOARD
FLOW CONTROL SWITCH: SKD-11 Performance Range Flow from 0 to 15m3/h. The SKD-11 flow control starts the pump automatically when pressure decreases (for example taps are opened) and stops it when there is no flow/water shortage (for example taps are closed). It can be used for drinking water or nonpotable water piping systems.
Operating limits Pipe Water Temperature 0 - 60°C (not frozen) Ambient Temperature 0 - 45°C
Technical Features Rated Voltage: 220VAC, 50Hz Maximum current: 30 Amp Protection grade: IP65 Starting pressure: 1.2bar Maximum pressure: 10bar Inlet/outlet size: (1¼” x 1¼”) BSP